The cooling tower for daily operation management?

by:Huatal     2020-04-21
In order to ensure the work under the cooling tower in a poor state, it is necessary to do the daily operation management of cooling tower operation, it mainly includes the following aspects: 1. According to the production load, weather conditions, and the tower equipment status, the preparation of the operation of the economic and reasonable way. 2. Timing measurements of the cooling tower operation parameters, usually once every 2 h. Record contents including the meteorological conditions of cooling tower operation condition and related note, etc. 3. According to winter weather conditions, production load, and cooling equipment status, the preparation of the cooling tower of winter running scheme and anti-freezing measures. 4. Changes and reasons of timing analysis of cooling tower thermodynamic property, analyzing the economic efficiency of the cooling tower. 5. Often patrol inspection, record the cooling tower and circulating water system defects, and report to the relevant parties. 6. Reasonable adjustment and allocation of the parallel operation of the cooling tower water load, make comprehensive after cooling water temperature is low. Within a reasonable adjustment of cooling tower water level of each tank, uniform water density distribution is reasonable. Are not allowed to match the tank water level is too high and direct spillover, each with water tank water level difference in the tower at the same time should be no greater than 10% ~ 15%, the same type of cooling tower outlet water temperature difference is less than l ℃. 7. Right to the implementation of the economic and reasonable drainage plan; Observation of cooling equipment fouling conditions, water quality situation; Regularly check, for the normal work of the sewer system, and make relevant records. 8. Observe leakage of cooling tower equipment, including collecting basin and circular ditch. Cooling tower is offline, but from the water level change to judge; Cooling tower runtime may change from the supply of water and water level to judge. Should organize inspection when necessary. 9. Often observed in each cooling tower set pools and circular ditch water, make the different parts of water level difference is not greater than 15%. Adjusting supplement water in time, to maintain the normal work of water circulating pump and avoid the water to overflow. Found that circular ditch water level before and after the filter is more than 10 cm, it indicates that the filter is blocked, should immediately clean the filter. 10. Correctly and reasonably adjust the winter operation scheme and anti-freezing measures, including: reasonable cooling tower in winter operation service; In special antifreeze water distribution device; Time temperature measurement and adjust wind deflector diligently; Timely removal of harmful hang ice; To shut down the equipment vent water or circulating water protection anti-freezing measures, etc. 11. Of rotating equipment such as mechanical ventilation cooling tower fan, in the operation of the monitoring should be strengthened; Mechanical friction sound, leaf swing, motor, gearbox and bearing oil level temperature change and the oil pump operation, and so on and so forth. 12. During the cold season, should prevent running in the condensate supercooling, according to the meteorological condition and load condition, after calculation and experiments after winter operation cycle of water, can determine the shutdown circulating pump sets and the cooling tower. Post: http://www cooling tower manufacturer. gdrf1688. com/case- 2 - 1. html < br>
Jiangsu Huatal Cooling Technology Co., Ltd. is recognized as one of the leading manufacturer of in China.Trust in us and make Jiangsu Huatal Cooling Technology Co., Ltd. your cooling tower manufacturer supplier. Our products will bring more economic value to you.
Helping the needy water cooling tower industries with quality products had been our main goal and we have succeeded in providing simple and effective solutions which has a huge scope to be implemented in the near future. Go to Huatal Cooling Tower to know more about us.
Jiangsu Huatal Cooling Technology Co., Ltd. deems that we can drive consumer transactions using high-tech tools like artificial intelligence and cognitive data sets.
People are more likely to listen to an expert than just anyone off the street. So, while pack mentality is important, having a relevant expert speak to the effectiveness of a brand's product as Huatal is essential to converting new consumers as well.
Our commitment to equal employment and diversity is a global one as we serve customers and employ people around the world. Jiangsu Huatal Cooling Technology Co., Ltd. finds it as a business imperative that is essential to thriving in a competitive global marketplace.
Custom message