Why will drift water cooling tower manufacturer about the cooling tower?

Cooling tower as essential to the cooling water recycling system equipment, normally drift rate can not exceed 3% of the total flow of the cooling tower water cooling tower, but many enterprises of the cooling tower at run time cooling tower FengKouChu have apparent white fog, and even serious with light rain, wet cooling tower are within 30 meters around, like this kind of situation that drift water cooling tower there are serious problems, need to be settled as soon as possible. First of all, to explain why the cooling tower water drift phenomenon, because of cooling tower belongs to the water cycle cooling equipment, due to the tower of the circulating water temperature is higher than that of outdoor air temperature, temperature difference between existence, white mist arises because of heat, this situation is more obvious in winter; Main by fan and cooling tower convulsions, cooling tower in the process of convulsions will take a lot of air volume, so to speed up the circulating water floating water phenomenon. Below, to analyze the cause of the cooling tower water drift: 1, the cooling tower to cut corners, without bleaching water prevention measures. Now a lot of cooling tower manufacturers in order to save costs, can be in cooling tower materials fudging, normally have put floating along the water cooling tower before they leave the factory measures, such as fixed spray system of cooling tower, must be installed with v-shaped water receiver, and rotating water distribution system of cooling tower on the hose have manger, as long as the match to the two kinds of waterproof measures, cooling tower water drift phenomenon basic can solve. 2, cooling tower water pump pressure. Once the cooling tower water pump pressure is too big, can cause circulating water flow rate is too large, will directly result in cooling tower water splashing. 3, cooling air volume is too large. Cooling tower air flow depends on the cooling tower motor and fan power Angle, big air volume is also led to one of the main reasons for the phenomenon of water cooling tower. 4, cooling tower water temperature is too high. Cooling tower water temperature too high can cause tower inside and outside temperature difference is too big, outdoor air drawn into the cooling tower, tower of hot water, heat exchange, and then the cold air into hot and humid air, the hot and humid air contains a lot of water molecules, and then be sent to the tower, hot and humid air outside the tower again meet cold air, instant condenses into fog or water droplets, will form the floating water cooling tower. 5, cooling nozzle or pipe damage. Damage can lead to the cooling tower and cooling nozzle and the pipe local area a lot of water, the greater the pressure big splash water phenomenon, the greater the fan suck water molecules. 6, cooling tower packing jams. After cooling tower filler plug can cause water phenomenon in the circulating water, cooling tower memory after water drift can also lead to water.

Service-based companies as Jiangsu Huatal Cooling Technology Co., Ltd. are increasingly becoming more popular internationally.

Are you interested in buying ? We also have all kinds of in offer. Visit Huatal Cooling Tower to know more and order, we have them at pocket friendly prices.

There are different types of , mainly water cooling tower and water cooling tower.

First, in sparking the initial idea for a company based on manufacturing technology; and second, in designing a solution that could meet a clear market need for solving issues related to cooling tower manufacturer water cooling tower.

Provide cooling tower manufacturer strategists with enough funds to adequately market our company and the products and services it provides.

GET IN TOUCH WITH Us
recommended articles
knowledge Solution News
Working Principle of Cross-Flow Closed Cooling Tower
Cross-flow closed cooling tower is a common industrial equipment used to cool hot water or other fluids. Its working principle is as follows
Two methods for closed cooling tower cleaning
The closed cooling tower is exposed to harsh outdoor conditions for a long time, the dust in the air, the rain erosion and corrosion, and the fungus that may appear in the internal operation of the closed cooling tower, etc., which are very harmful to the cooling tower, so the cleaning of the closed cooling tower is very important. Normally the closed cooling tower cleaning can be done in two methods, shutdown cleaning and cleaning during operation.
The cooling capacity's key determinants of closed cooling tower
The operation principles of closed cooling tower are heat exchange and heat transfer between the air and spray water and the liquid flow in the coil pipes, so the closed cooling tower is also a heat dissipation device, which has the advantages to reduce energy and water consumption. The temperature reduce effect of the closed cooling tower is also extraordinary.
How to select closed cooling tower Part.2-- Huatal Closed Cooling Tower
When selecting a closed cooling tower, an appropriate closed cooling tower can be selected by calculating the required cooling water, cooling capacity, power and other parameters. There are many kinds of materials for the production of closed cooling towers, such as aluminum and zinc plate, stainless steel plate, glass fiber reinforced plastic and other materials.
The difference between outer plate materials of closed cooling tower
The price difference between different closed cooling tower price manufacturers is quite large. Where is this price difference reflected? In fact, it is very simple, everyone get what they pay for. Diffenert outer plate materials have their own true cost. Now let's take a look at the material properties and price differences of the closed cooling tower casing!
The advantages of closed cooling tower system -- Huatal Cooling Tower
During our sales, our customers always asking about why Huatal focused on closed cooling tower system. So today we would like to share the advantages of closed cooling tower system with you.
no data

CONTACT US

Contact person: Mr.Jeff
Mobile/Whatsapp: +86 18112352129
Tel: +86 0510-85162129
Fax: +86 0510-85162326
Company email: sales01@huatal.com
Address: National industrial design park, binhu district, wuxi city, jiangsu province
Factory address: Jiangxi industrial concentration zone, xinwu district, wuxi city, jiangsu province

Jiangsu Huatal Cooling Technology., Ltd. 

Complimentary Samples For You And Technical Consultation At Your Convenience

Copyright © 2025 Jiangsu Huatal Cooling Technology., Ltd. -www.htcoolingtower.com | Sitemap Privacy Policy
Customer service
detect