Cooling tower manufacturers about the floating water cooling tower standard rate is generally in the circulating water 2% 5%, at the time of operation, spray cooling tower can be seen that a lot of small water droplets, like a white mist, drift water cooling towers can be rather serious. Drift water cooling tower is many cooling tower manufacturer meet, but has not been very good to solve problems. Water chiller system, any form of cooling tower in the state of work is more or less the existence of the drifting water phenomenon. Especially in the open cooling system, circulating water, direct contact with atmospheric bacteria and dust in the air is kept within the tower, to cause circulating water turbidity increased, algae formed in wet places of the tower, from the surface increases the resistance, pipeline and aproll system reduces the cooling efficiency, corrosion of the tower body. The float the water droplets to the atmosphere can also be possible with bacteria and pollution sources, damage to the atmosphere, or people. One of the main causes of drift, cooling tower water 1, cooling tower fan draught by the small water droplets from the ram mouth outside the cooling tower. 2, saturation is the hot and humid air after leaving the cooling towers in the cold air saturated state, condenses into water droplets, the formation of rinsing water. 3, water out of the packing into the tuyere float. Two, for these reasons, prevent drift water cooling tower can control from the following aspects: 1, the moving of the water square cross-flow fan cooling tower based on large, wide hakaze machine, the air volume of cases, increasing the windward side can reduce the fan speed, thereby reducing water droplets speed, reduce the ram rinsing water. 2, packing after assembly into the wind is a honeycomb diverter, have good uniform wind effect, improve the heat transfer intensity and stability of the water. Into the wind side tilt Angle of 30 ° to the tower, the air can be imported, and the water is unable to spatter, effectively reduces the floating water loss. 3, increase the fan blade width, lower the fan speed, so as to alleviate cooling tower floating water loss; 4, need to increase the natural gravity of water nozzle and add water retaining components between filler and cloth pool, thus to improve the way of cooling tower water distribution; 5, change turned, clean up the hose, if caused direct replacement pump pressure is suitable pumps; Six, the transformation wet cooling tower packing, on the basis of the original packing increase packing into and out of the wind section water structure, to make the packing moisture limit the return back, reduce fan away the water.

These cooling tower manufacturer water cooling tower are meant to serve as a guide for business owners on how to both identify potential opportunities for transformative innovation and how to adapt to the constantly changing technologies of today.

Jiangsu Huatal Cooling Technology Co., Ltd. ’s sole aim is to provide exquisite and unheard of features to the concept of producing technology.

With wide range of [分类关键词] products of top quality in offer, Jiangsu Huatal Cooling Technology Co., Ltd. will definitely be your best option for cooling tower manufacturer solution. Do feel free to contact us at Huatal Cooling Tower.

GET IN TOUCH WITH Us
recommended articles
knowledge Solution News
Selection of pipeline for closed cooling tower -- Huatal Closed Cooling Tower
Closed cooling tower will be given priority when choosing cooling equipment in various industries, and this is also the case in the food industry, so the selection of closed cooling tower pipeline is also very important. Today we're going to share with you about the difference in terms of material.
Chinese New Year Holiday
Our office will be closed from Feb 6th 2021 to Feb 17th 2021 for the Chinese New Year Holiday.We will back to office by Feb 18th 2021.
The position of closed cooling tower in circulating water cooling system Part.2 --Huatal Cooling Tower
The previous article we explained that the general scheme of circulating water cooling system is constituted by tower structure, heat exchanger coil pipes, fills, circulating pump, water basin etc..., is this cooling equipment the closed cooling tower (also called a closed circuit cooling towers, closed loop cooling tower)?
The Cause Of Closed Cooling Tower Water Leakage
There are many reasons will caused the water leakage of closed cooling tower, and the aging of traditional closed cooling tower is only one of them. Will the new tower leak too? The answer is yes. However, this is not an irreversible fault. First of all, we should investigate the cause and then give a detailed solution to the fault.
no data

CONTACT US

Contact person: Mr.Jeff
Mobile/Whatsapp: +86 18112352129
Tel: +86 0510-85162129
Fax: +86 0510-85162326
Company email: sales01@huatal.com
Address: National industrial design park, binhu district, wuxi city, jiangsu province
Factory address: Jiangxi industrial concentration zone, xinwu district, wuxi city, jiangsu province

Jiangsu Huatal Cooling Technology., Ltd. 

Complimentary Samples For You And Technical Consultation At Your Convenience

Copyright © 2025 Jiangsu Huatal Cooling Technology., Ltd. -www.htcoolingtower.com | Sitemap Privacy Policy
Customer service
detect