loading

Huatal - Closed Cooling Tower Manufacturer & Industrial Cooling Tower Solution Provider

Calculate the cooling tower high temperature weather conditions

In the industrial circulating water cooling design specification ( GB / T50102 - 2003). For high water temperature of cooling towers, used in cooling step, cooling circulating water of high temperature cannot exceed production need high temperature, and in the calculation of the cooling water high temperature, want to consider the meteorological conditions of the environment, and meteorological conditions to comply with the requirements for temperature calculation: the equipment using the surrounding environment of meteorological condition and dry wet bulb temperature have a bigger impact on the use of cooling tower, if calculation method calculated, regardless of weather conditions will lead to the use of calculation results and the actual water temperature caused by mismatch, cause power consumption is too large, or the problems such as insufficient cooling capacity. Weather conditions: 1. Using the meteorological data of high cooling tower water temperature is calculated after a 2 - The use of three years, according to the theory of thermal phase to compute the average of a year, theory of thermal phase is concentrated in the June, July and August in China. 2. At the time of equipment used, if more strict with cooling water temperature, can be appropriate to improve meteorological conditions; If the device to request is not high, the water temperature of cooling water can be appropriate to reduce meteorological conditions. 3. Wet bulb temperature requirements, should according to the statistical frequency of 5% wet bulb 10% on average. Meteorological parameters statistical methods: 1. Wet bulb frequency statistics method: according to the statistics of the average daily dry bulb temperature and wet bulb separate statistics, and notification and trend analysis on a graph, according to the drawing of drawing curve chart for the wet bulb for calculating temperature of the same point in time. 2. The curve of the dry bulb temperature and relative humidity statistical methods: dry bulb temperature and relative humidity were graphed, telling the graph on the same frequency dry bulb temperature and wet bulb temperature relatively calculated value. 3. The average daily wet bulb temperature of wet bulb temperature curve drawing method: the main statistics and graph, according to the graph drawing, find out the design frequency under the wet bulb temperature value, and find out and dry bulb temperature and relative humidity, air pressure corresponding to the daily average. 4. Dry bulb temperature curve drawing method: the main statistical average dry bulb temperature, and a graph, according to the graph to find out in the design of frequency under the dry bulb temperature, as the calculated value, and benefits in the original data corresponding to the dry bulb temperature and relative humidity. 5. Enthalpy curve drawing method: according to the daily average dry wet bulb temperature and atmosphere pressure to calculate the average enthalpy, again according to the calculation of the daily average enthalpy graph, according to the design frequency curve calculated enthalpy, and find the day and the enthalpy corresponding to the average dry bulb temperature and the sheet temperature, atmospheric pressure. Fish in closed cooling tower heat transfer power is in the process of mass transfer of water saturated moist air into the cooling tower outside the surface of the moist air enthalpy difference. Wet air enthalpy depends on air temperature for the first goal.

The cooling tower manufacturer approach to water cooling tower is becoming increasingly popular; consequently, there is a surge in the demand for .

Through our culture, our drive and the expertise of each individual employee, Jiangsu Huatal Cooling Technology Co., Ltd. is uniquely positioned to provide best-in-class services to a global customer base.

In the boundless Chinese market, there are a number of enterprises that provides water cooling tower cooling tower manufacturer of their own brand over the years, but few have won more support from customers on the international stage than Huatal.

GET IN TOUCH WITH Us
recommended articles
knowledge Solution News
Will The Closed Cooling Tower Scale?
When closed cooling tower is selected by customers as cooling equipment, the advantages of closed cooling tower are mainly in energy saving, environmental protection, long life and not easy to scale, and occasionally there are blockages. What is the reason for scaling? Can closed cooling tower be 100% free from scaling?
The Cause Of Closed Cooling Tower Water Leakage
There are many reasons will caused the water leakage of closed cooling tower, and the aging of traditional closed cooling tower is only one of them. Will the new tower leak too? The answer is yes. However, this is not an irreversible fault. First of all, we should investigate the cause and then give a detailed solution to the fault.
Will the air inlet of counterflow closed cooling tower freeze?
During winter season, the air inlet of counter flow closed cooling tower is easy to freeze.
Open cooling towers VS closed cooling towers
How to correctly choose between open cooling towers and closed cooling towers? There are water-saving cooling towers as well as power-saving cooling towers. There are small-sized cooling towers as well as those suitable for cold regions. This article will help you learn more about open cooling towers and closed cooling towers, and assist you in choosing the right cooling tower.
How to select closed cooling tower -- Huatal Closed Cooling Tower
With the popularity of closed cooling towers in various industries, more and more closed cooling towers are used. Many people will consider directly choosing closed cooling towers from a long-term perspective, but they do not know how to choose. Next, we will introduce the closed cooling tower in detail for you.
no data

CONTACT US

Contact person: Mr.Jeff
Mobile/Whatsapp: +86 18112352129
Tel: +86 0510-85162129
Fax: +86 0510-85162326
Company email: sales01@huatal.com
Address: National industrial design park, binhu district, wuxi city, jiangsu province
Factory address: Jiangxi industrial concentration zone, xinwu district, wuxi city, jiangsu province

Jiangsu Huatal Cooling Technology., Ltd. 

Complimentary Samples For You And Technical Consultation At Your Convenience

Copyright © 2026 Jiangsu Huatal Cooling Technology., Ltd. -www.htcoolingtower.com | Sitemap Privacy Policy
Customer service
detect