The Cause Of Closed Cooling Tower Water Leakage

Water leakage reasons:

  1. The tower body corrosion causes water leakage: this is because of long-term use, environmental corrosion of the tower body manufacturing raw materials for corrosion, resulting in uneven thickness of the tower body, in the thickness of the local contrast will appear damaged water leakage. Leakage can improve the water consumption. If it is a FRP cooling tower, we can choose to finish the appearance, polish and clean, degreasing with cleaning agent, reinforcing with epoxy repair agent glass fiber belt. If it is the material of magnesium, aluminum and zinc plate, we should consider replacing part of the magnesium, aluminum and zinc alloy plating steel sheets.

  2. The corrosion at the steel plate connection of the cooling tower water basin causes water leakage: In the assembly of the cooling tower, the magnesium, aluminum and zinc plates are rubbed with coke to be compacted and sealed. Long time operation received the impact of spray water, tower deformation, sealant off will cause leakage at the joint. Because the spray water is concentrated in the bottom of the pool, leakage will need to constantly replenish the spray water. Closed cooling tower block is aluminized zinc plate, we can fill the sealant from the inner gap of the cooling tower to stop the leak.

  3. Water leakage in the pipes connecting joint: When connecting line will connect - some of the flange and elbow, when connect we between two connection head sealing ring, pipeline leaks, most of the situation in the cause of the connection is not lost, seal damaged or position displacement will cause unstable cooling towers, closed cooling tower water leakage fault how to solve the leaking.

    The Cause Of Closed Cooling Tower Water Leakage 1

The above is what we share about the leakage of closed cooling tower. If you are interested in our topic or have different opinions, please contact us, email: sales01@huatal.com, or our sales cell phone: +86 18800576579 or +86 18661061285.

prev
Daily Management And Maintenance Of Closed Cooling Tower
The cause of closed cooling tower water leakage Part.II
next
recommended for you
no data
Get in touch with us

CONTACT US

Contact person: Mr.Jeff
Mobile/Whatsapp: +86 18112352129
Tel: +86 0510-85162129
Fax: +86 0510-85162326
Company email: sales01@huatal.com
Address: National industrial design park, binhu district, wuxi city, jiangsu province
Factory address: Jiangxi industrial concentration zone, xinwu district, wuxi city, jiangsu province

Jiangsu Huatal Cooling Technology., Ltd. 

Complimentary Samples For You And Technical Consultation At Your Convenience

Copyright © 2025 Jiangsu Huatal Cooling Technology., Ltd. | Sitemap Privacy Policy
Customer service
detect