Cooling tower manufacturers about the floating water
cooling tower standard rate is generally in the circulating water 2%
5%, at the time of operation, spray cooling tower can be seen that a lot of small water droplets, like a white mist, drift water cooling towers can be rather serious.
Drift water cooling tower is many cooling tower manufacturer meet, but has not been very good to solve problems.
Water chiller system, any form of cooling tower in the state of work is more or less the existence of the drifting water phenomenon.
Especially in the open cooling system, circulating water, direct contact with atmospheric bacteria and dust in the air is kept within the tower, to cause circulating water turbidity increased, algae formed in wet places of the tower, from the surface increases the resistance, pipeline and aproll system reduces the cooling efficiency, corrosion of the tower body.
The float the water droplets to the atmosphere can also be possible with bacteria and pollution sources, damage to the atmosphere, or people.
One of the main causes of drift, cooling tower water 1, cooling tower fan draught by the small water droplets from the ram mouth outside the cooling tower.
2, saturation is the hot and humid air after leaving the cooling towers in the cold air saturated state, condenses into water droplets, the formation of rinsing water.
3, water out of the packing into the tuyere float.
Two, for these reasons, prevent drift water cooling tower can control from the following aspects: 1, the moving of the water square cross-flow fan cooling tower based on large, wide hakaze machine, the air volume of cases, increasing the windward side can reduce the fan speed, thereby reducing water droplets speed, reduce the ram rinsing water.
2, packing after assembly into the wind is a honeycomb diverter, have good uniform wind effect, improve the heat transfer intensity and stability of the water.
Into the wind side tilt Angle of 30 ° to the tower, the air can be imported, and the water is unable to spatter, effectively reduces the floating water loss.
3, increase the fan blade width, lower the fan speed, so as to alleviate cooling tower floating water loss;
4, need to increase the natural gravity of water nozzle and add water retaining components between filler and cloth pool, thus to improve the way of cooling tower water distribution;
5, change turned, clean up the hose, if caused direct replacement pump pressure is suitable pumps;
Six, the transformation wet cooling tower packing, on the basis of the original packing increase packing into and out of the wind section water structure, to make the packing moisture limit the return back, reduce fan away the water.