< p> floating water rate is an important index of
cooling tower water saving performance, a big wave water rate cooling tower water consumption.
Cooling tower water loss including three parts: water evaporation loss, the wind gone with the wind water loss and pollution damage.
< / p> < p> evaporative water loss is the loss of the cooling tower shall not avoid, and pollution losses are relatively less, saving water mainly reflects in the water to reduce the wind gone with the wind.
< br /> < / p> < p> water floating in unit time (
Mass flow rate, the unit kg/h)
With the cooling water flow into the tower (
Mass flow rate, the unit kg/h)
The ratio of the.
Installation of water removal is one of the measures to reduce the wind gone with the wind water, but at the same time will increase < / p> < p> and the resistance of the tower, rising energy consumption, low cooling capacity of cooling tower.
< p> floating rate is higher when the water cooling tower fill water is more, and has been part of the cooling water was taken in thermal efficiency decline.
Should also include other water dripping on the packing outside the cooling splash of loss < / p> < p> section.
Cooling tower floating water loss is usually 1 ~ 2%!
As long as meet the national standard of the cooling tower, water floating rate low about 0.
015, which can meet the national water conservation to recognize the cooling tower is low, almost negligible, built when buying < / p> < p> about buying through standard and meet the national water saving's cooling tower.
< / p> < p> - drift water cooling tower standard rate
Is in the loop water of 2%
5%, at the time of operation, spray cooling tower can be seen that a lot of small water droplets, like a white mist, drift water cooling towers can be rather serious.
< / p> < p> drift cooling tower water solution: < / p> < p> 1, add big fan blade width, low fan speed, thus slow cooling tower floating water loss.
< / p> < p> 2, to increase the natural gravity water nozzle and add water retaining components between filler and cloth pool, thus to improve the way of cooling tower water distribution.
< / p> < p> 3, in turn, clean up the spill water pipe, if the pump pressure is too large for combined optimum pump directly.
< / p> < p> 4, wet cooling tower packing, on the basis of the original packing increase packing into and out of the wind section water structure, to make the packing water limit the return back, reduce fan away the water.
< / p> < p> < br /> < / p> < br /> < / p> < br>
cooling tower manufacturer are among the best and the long known , which plays an essential part in automatic manufacturing.
Jiangsu Huatal Cooling Technology Co., Ltd. provides which will help you water cooling tower in a durable and reliable way. To learn more, go to Huatal Cooling Tower.
Jiangsu Huatal Cooling Technology Co., Ltd. has extented its range of manufacturing scale, which satisfys customers' needs.
Jiangsu Huatal Cooling Technology Co., Ltd. ’s mission is to provide you with an outstanding member/Customer benefit that helps you meet your organization’s objectives.