loading

Huatal-Closed-circuit cooling tower manufacturer & industrial cooling tower solution provider 

   

Closed cooling tower operation using the matters needing attention

by:Huatal     2020-03-24
1 a: closed cooling tower using the environment request. To avoid acid exhaust, severe explosive dust, soot, the excess of water vapor in place; 2. Should be placed next to the buildings, and keep enough distance between inlets, ( 0. 5 - 3 m, depending on the type and decide) ; 3. Placed well type wall, cause heat removal failure should be alert to damp and hot air reflow, special circumstances can consider to lead the wind device; 2: closed cooling tower installation, use and matters needing attention in the operation of the closed type cooling tower installation: closed cooling tower should be horizontally installed in the ventilation environment all around, don't get too close to the walls, like get close to the wall, to many to 1. 5 meters, the height of the outlet should be higher than near the top of the wall. Pipeline configuration reasonable pipeline configuration can guarantee the normal operation of the closed cooling tower and economic operation. Line configuration should comply with the refrigeration system design specifications. Closed cooling tower and shell and tube type closed cooling tower, the liquid pipe stands at the junction of vertical line and horizontal line should make U deposit liquid form of connection, in order to prevent the refrigerant flow towards the direction of the small resistance, influence the cooling effect. Water circulation system of water in the process of evaporation, the minerals in the water and other impurities in water tank, water tank, easy to corrosion generated scale, please regular blowdown and cleaning tank once a month, the floating ball valve, relief valve and check regularly, generally in the operation of the device can look at it. In winter the temperature is lower, ( The northern region) Also can stop the water pump, fan run separately, so can reduce the pump power consumption, also can prevent the freezing circulating water problem, no matter in winter some reason under the condition of the pump stop running, especially the water pump will be water cycle system, antifreezing measures. Also on the water tank can be mounted to the electric heater to prevent freezing.

With new and upcoming social commerce technologies, the biggest change for cooling tower manufacturer marketers will be a shift in focus from branding to lead generation and conversion.
At Jiangsu Huatal Cooling Technology Co., Ltd. , we make sure everything we do honors that connection – from our commitment to the highest quality in the world, to the way we serve our customers and communities to do business responsibly. We are looking forward to becoming trusted supplier of every customer, inquire us at Huatal Cooling Tower!
In a nutshell, is actually an ultimate solution for water cooling tower and underestimating its value cost you higher than anything else. So grab it before you miss the boat.
Custom message
Chat Online 编辑模式下无法使用
Leave Your Message inputting...