Cooling tower, in the actual operation of the circulating water loss is inevitable, as to how many most losses shall be calculated according to the configuration of the cooling tower;
The cooling tower circulating water loss mainly due to the following points;
< br /> 1, the natural evaporation loss: FRP cooling tower water cycle system is due to open, direct contact with the atmosphere of circulating water, hard to avoid can natural evaporation, but natural evaporation quantity is relatively small, about 0 of total water cycle.
2 -
0.
3%.
< br /> 2, floating water loss, due to the rotation of the cooling tower operation depend mainly on the tower fan, air flow, the hot and humid air exhaust to the outside of the tower;
Cooling air volume is larger, the greater its suction, hot and humid contains a large number of water molecules in the air, the water molecules tend to be fan suction exhaust to the outside of the tower, which is why had white mist cooling tower ram or floating water phenomenon;
Under normal circumstances the cooling tower water in 1 - natural
3%, but if there is no installation
closed cooling tower water or manger, then cooling tower of the floating rate can reach 10 - water
About 20%, which is why some cooling tower with light rain yes, within 50 meters around the main reason is that there is no water closed cooling tower equipment.
< < br /> < / p> < < br /> < / p> 3, the loss of or damage to the wind: cooling towers into the wind window position in wind is larger when there will be a water wave, the main reason is caused by the wind, in the event of this kind of problem can be properly add some manger or guide plate.
< br /> 4, blowdown, desilting loss: FRP cooling tower water pans because in outdoor environment, will inevitably have a sandy silt, algae, dirt, etc. , cooling tower in the process of sewage also can produce the loss of the circulating water.
< br /> winter cooling tower circulating water loss is relatively less, is often in the summer, the cooling tower both in natural water drift and evaporation is large, so proposal on a hot summer, can increase the cooling tower fill water, not only can solve the cooling tower water loss but also can reduce the water temperature.
< br /> < br /> < br>
Most people who see a in operation for the first time are amazed at how well the water cooling tower is managed.
More about the most suitable , visit Huatal Cooling Tower to get your offer!
Jiangsu Huatal Cooling Technology Co., Ltd. can promise that cooling tower manufacturer is one of the best products sold in the worldwide market at present.
The stability of the system, controllability of the water cooling tower process, and mobility of the machines provide with a flexible and reliable cooling tower manufacturer system.